Surface Flashover of Solid Insulator in Air
Abstract
This paper is aimed at the propagation of discharges over a surface of insulator and the development of an analytical flashover model in air at atmospheric pressure. The experimental results show that the critical conditions of flashover are over the half of creeping distance. Basing on electrical equivalent circuit and the impedance criterion, we developed a relationship giving the flashover voltage UFOV. This relationship suggests that flashover voltage is function of the discharge thermal parameters, the capacitance and the resistance of solid insulator and the propagation condition of the discharge. The UFOV computed using relationships we established elsewhere are found in a good accordance with the experimental ones.
Mohammed El Amine SLAMA1,2, Abderrahmane BEROUAL2,1 Alain GIRODET1 and Paul VINSON1
1 SuperGrid Institute, 130 rue Leon Blum Villeurbanne 69100, France
2Ecole Centrale de Lyon, AMPERE CNRS UMR 5005, 36 Avenue Guy de Collongue, 69134 Ecully, France
amine.slama@ec-lyon.fr
ISH 2015 PILZEN : 19 th international Symposium on High Voltage Engineering
24th 28th August 2015